Scientific Library of Tomsk State University

   E-catalog        

Normal view MARC view

Broadband spectral verification of optical clearing reversibility in lung tissue L. R. Oliveira, R. M. Ferreira, M. R. Pinheiro [et al.]

Contributor(s): Oliveira, Luís R | Ferreira, Ricardo M | Pinheiro, Maria Rosario | Silva, Hugo Filipe | Tuchin, Valery V | Oliveira, Luís ManuelMaterial type: ArticleArticleContent type: Текст Media type: электронный Subject(s): легочная ткань | оптическое просветление | показателей преломления | механизм обезвоживания тканейGenre/Form: статьи в журналах Online resources: Click here to access online In: Journal of biophotonics Vol. 15, № 10. P. e202200185 (1-7)Abstract: The increase of tissue transparency through sequential optical immersion clearing treatments and treatment reversibility have high interest for clinical applications. To evaluate the clearing reversibility in a broad spectral range and the magnitude of the transparency created by a second treatment, the present study consisted on measuring the spectral collimated transmittance of lung tissues during a sequence of two treatments with electronic cigarette (e-cig) fluid, which was intercalated with an immersion in saline. The saline immersion clearly reverted the clearing effect in the lung tissue in the spectral range between 220 and 1000 nm. By a later application of a second treatment with the e-cig fluid, the magnitude of the optical clearing effect was observed to be about the double as the one observed in the first treatment, showing that the molecules of the optical clearing agent might have converted some bound water into mobile water during the first treatment.
Tags from this library: No tags from this library for this title. Log in to add tags.
No physical items for this record

Библиогр.: 24 назв.

The increase of tissue transparency through sequential optical immersion clearing treatments and treatment reversibility have high interest for clinical applications. To evaluate the clearing reversibility in a broad spectral range and the magnitude of the transparency created by a second treatment, the present study consisted on measuring the spectral collimated transmittance of lung tissues during a sequence of two treatments with electronic cigarette (e-cig) fluid, which was intercalated with an immersion in saline. The saline immersion clearly reverted the clearing effect in the lung tissue in the spectral range between 220 and 1000 nm. By a later application of a second treatment with the e-cig fluid, the magnitude of the optical clearing effect was observed to be about the double as the one observed in the first treatment, showing that the molecules of the optical clearing agent might have converted some bound water into mobile water during the first treatment.

There are no comments on this title.

to post a comment.
Share