Scientific Library of Tomsk State University

   E-catalog        

Normal view MARC view

Light-emitting-diode Fourier-transform spectroscopy of HD16O between 11200 and 12400 cm-1 L. N. Sinitsa, V. I. Serdyukov, E. R. Polovtseva [et.al.]

Contributor(s): Sinitsa, Leonid N | Polovtseva, Elena R | Shcherbakov, Anatoly P | Bykov, Alexander D | Voronin, Boris A. физик | Serdyukov, Viktor I | Томский государственный университет Факультет инновационных технологий Научные подразделения ФИТMaterial type: ArticleArticleSubject(s): светоизлучающие диоды | Фурье-спектроскопия | тяжелая водаGenre/Form: статьи в журналах Online resources: Click here to access online In: Proceedings of SPIE Vol. 9680 : 21st International Symposium Atmospheric and Ocean Optics: Atmospheric Physics, June 22-26, 2015, Tomsk, Russian Federation. P. 96800G-1-96800G-5Abstract: The absorption spectrum of monodeuterated water, HDO has been investigated between 11200 and 12400 cm-1. The spectrum has been recorded using IFS-125M interferometer with spectral resolution of 0.05 cm-1. For measurements White’s-type cell were used. The bright light emitting diode (LED) EDEI-1LS3-R was applied as a source of radiation. Signal to noise ratio was about 104. The spectral line parameters - line positions, intensities and half-widths were obtained by least square fitting. As a result of the spectrum analysis the line list containing more than 1500 lines was created. The spectral line parameters have been compared with the previous measured and calculated data. © (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Tags from this library: No tags from this library for this title. Log in to add tags.
No physical items for this record

Библиогр.: 25 назв.

The absorption spectrum of monodeuterated water, HDO has been investigated between 11200 and 12400 cm-1. The spectrum has been recorded using IFS-125M interferometer with spectral resolution of 0.05 cm-1. For measurements White’s-type cell were used. The bright light emitting diode (LED) EDEI-1LS3-R was applied as a source of radiation. Signal to noise ratio was about 104. The spectral line parameters - line positions, intensities and half-widths were obtained by least square fitting. As a result of the spectrum analysis the line list containing more than 1500 lines was created. The spectral line parameters have been compared with the previous measured and calculated data. © (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.

There are no comments on this title.

to post a comment.
Share